XK-W1099 220V Temperature and Humidity Meter Display Relay Module - Thermostat
XK-W1099 220V Temperature and Humidity Meter Display Relay Module - Thermostat. It has a dual digital display and is the same It can measure both temperature and humidity at the same time. Cooling/heating and humidifying/dehumidifying functions can be used when the necessary equipment is connected. It has high accuracy.
Features
- Supply Voltage: 220VAC
- Relay Output Contact Capacity: 10A (Direct Output)
- Measurement Temperature Range: -20 ~ 80°C
- Measurement Humidity Range: 0 ~ 100% RH
- Accuracy: ±1°C, 0.1% RH
- Internal Sensor
- Sensor Length: 1m
User Manual
Setting the Initial Temperature
Press and release the 1 key in the up arrow at the bottom of the temperature screen. Then, press and hold the up arrow key for 3 seconds, when the temperature value you want begins to blink. You can adjust the value with the up or down arrow keys.
Setting the Temperature Value to Stop
Press and release the 1 key in the down arrow at the bottom of the temperature screen. Then press the down arrow key. Hold it for 3 seconds, when the temperature value starts to flash, you can adjust the desired value with the up or down arrow keys.
Setting the Initial Humidity Value
located at the bottom of the humidity screen Press and release the 2 button inside the up arrow. Then, hold down the up arrow button for 3 seconds. When the humidity value starts to blink, you can adjust the desired value with the up or down arrow keys.
The Humidity Value to Stop Adjustment
Press and release the 2 button in the down arrow at the bottom of the humidity screen. Then press and hold the down arrow button for 3 seconds. When the humidity value starts to blink, you can adjust the desired value with the up or down arrow keys.
Verifying Temperature and Humidity Value
This function is used to verify the value. If there is a deviation between the measured temperature and the actual temperature, you can use this function to verify the value. Verified Value = Measured value + verification value .For the temperature value, press the up-down arrow keys on the side of the temperature screen, for the humidity value, press and hold the up-down arrow keys under the humidity screen for 3 seconds. When you see the value 0.0 on the screen, you can adjust the verification value with the up and down arrow keys. After setting, wait for 5 seconds. It will automatically return to the display screen.
Resetting the Verification Value
While the device is running, press and hold the down arrow keys on both sides for 3 seconds. The number 888 will appear on the screen and The value will be reset automatically.
Product Guide
Connection