Notify me when its in stockP-11: in jog mode, no signal input and no signal connection.
P-12: self-locking mode, the state of the relay reverses once after each trigger.
P-13: after triggered, the relay will be pulled and disconnected after delaying a time; the trigger will be invalid during the delay.
P-14: after triggered, the relay will be pulled and disconnected after a delay of time; the trigger will be re-timed during the delay.
P-15: after triggered, the relay will be pulled and disconnected after the delay period; the accumulated timer will be triggered during the delay period.
P-16: after triggered, the relay is pulled and disconnected after delaying time A; During the delay, the reset is triggered (the relay is disconnected).
P-17: after triggered, the relay pulls for the duration of the signal, the input signal disappears, and then disconnects after a delay of a time; during the delay period, the relay is triggered again to keep pulling, and the timing stops until the last signal disappears, delay for a time and disconnect .
P-18: the relay will be pulled immediately after power-on and disconnected after a delay of one second; until the next power-up.
P-21: give the signal, the relay will be turned on after a time delay.
P-22: give a continuous signal, the relay will be pulled after the time is exceeded; when the signal disappears, the relay will turn on.
P-23: when the signal disappears more than once, the relay pulls; when there is a signal, the relay disconnects.
P-24: give a continuous signal. If the time exceeds, the relay is pulled in; When the signal disappears for more than an hour, the relay opens.
P-25: give a continuous signal, the relay turns off after a period of time; Give a continuous signal again, the relay turns off after a period of time
P-26: give a signal, the relay will be disconnected after pulling for a while; After the signal disappears, the relay will stop after a second pull.
P-27: There is a pulse signal (rising edge or falling edge), the relay is disconnected, there is no pulse signal, the relay pulls after a delay of time (considered as continuous high level or continuous low level pulse).
P-28: after power on, the relay will be pulled after a delay time until the power is turned off.
P-31: after the power is turned on, the relay pulls in at time A and turns off at time B in an infinite loop; the power is off.
P-32: there is a continuous signal, the relay pulls in one time, cut off time B, infinite loop; The signal disappears and the cycle is terminated.
P-33: signal once, relay pulls in one time, cut off time B, infinite loop; give another signal to end the cycle.
P-34: after power-on, relay A pulls in after delay time and disconnects after B pulls in time.
P-35: give a signal, after the delay time a, relay B pulls and pulls.
P-36: continuous signal is given, after A is exceeded, relay B is turned on and turned on; the signal disappears, the timing is cleared and the relay is closed.
P-37: There is a signal, after being turned off for a period of time, the relay will automatically disconnect, and the signal trigger will be counted after disconnection for the A + B period.
P-38: There is a signal, the relay will automatically cut off after the pull-in time - A, B counting after the cut-off time, it will automatically cut off after the pull-in time - again.
P-41: signal does not move; Signal disappears and triggers; Relay absorbs and combines after a delay to disconnect.
P-42: signal disappears, after the delay time, the relay turns off; after the delay time, the relay turns off.
P-43: signal disappears. After passing time A, the relay turns on; after delaying time B, the relay opens.
P-44: after power on, the relay pulls in time A and closes time B; after cycle C, the relay turns off and stops.
P-45: no action after power-on; After the signal is given, the relay pulls for a while and cuts off for a period of time B; After the C cycle, the relay is turned off and stopped; when the signal is given, it is operated again.
P-46: after the signal is given more than once, the relay continues to pull; the power stops.
P-47: once the signal passes, the relay pulls; when it pulls for time B, it is disconnected.
P-48: After continuously giving the signal more than once during time C, the relay cuts off and stops after time B.