Menu
Close
SIGN IN REGISTER
Forgot password?
Close
Cart

Relay Module with 12V Time Setting with 32 Modes - Boxed

Ratings & Reviews (0)
Comment
Show More: Timed Relay Boards
Brand: Motorobit
Product Code: RLK.ZMN.01.000077
Stokta 10+ ürün
270.00 TL + VAT
VAT Included: 324.00 TL

Relay Module with 12V Time Setting with 32 Modes - Boxed

Relay Module with 12V Time Setting with 32 Modes - Boxed. It is a 12VDC-powered time-controlled relay module. it can be set from 0.1~999 minutes Dec. there are 32 different operating modes.

Features

  • Supply Voltage: 12VDC
  • Output Load: 30VDC 10A/250VAC 5A
  • Operating Temperature December: -25~85°C
  • Dimension: 70.3x44.2x23mm
  • Memory Function

Setting the Mode

The device turns on when you press the encoder on the product for a short time once, and the device turns off when you press it again in the same way.

When you press for a long time (about 3 seconds), the mode appears on the selection screen. You can turn the encoder right-left to come to the mode you set.

When it comes to the set mode, it enters the mode when you press for a long time again.

You can set the duration by turning the encoder to the right-left and pressing on it for a short time.

When the adjustment is finished, the setting is saved when you press for a long time. (If there are A-B times in the mode, it switches to the other time. The setting is saved again in your long-term edition.)

Product Manual

32mods-with-box-instructions-1

32mods-with-box-instructions-2

Modes

P-11: in jog mode, there is no signal input and signal connection.

P-12: self-locking mode, the relay's state reverses once after each trigger.

P-13: after being triggered, the relay will be pulled and cut off after delaying a time; the trigger will be invalid during the delay.

P-14: after triggering, the relay will be pulled and cut off after a time delay; the trigger will be re-timed during the delay.

P-15: the relay will be pulled after it is triggered and cut off after the delay time; the accumulated timer will be triggered during the delay time.

P-16: after triggering, the relay is pulled and disconnected after delaying the A time; During the delay, reset is triggered (the relay is disconnected).

P-17: after being triggered, the relay pulls for the duration of the signal, the input signal disappears, and then disconnects after a delay of time; During the delay time, the relay is triggered again to hold the pull, and the timing stops until the last signal disappears, delay for a time, and disconnect.

P-18: the relay will be pulled immediately after the power is turned on and cut off after a delay of one second; until the next power.

P-21: give the signal, the relay will be pulled after a delay of time.

P-22: give a continuous signal, the relay will be pulled after the time is exceeded; the relay will be turned on when the signal disappears.

P-23: when the signal is lost more than once, the relay pulls out; when there is a signal, the relay interrupts.

P-24: give a continuous signal. If the time exceeds, the relay is pulled in; the relay is turned on when the signal is lost for more than an hour.

P-25: give a continuous signal, the relay pulls after passing a time; Give a continuous signal again, the relay shuts down after passing a time

P-26: give a signal, the relay will stop after being pulled for a while; the relay will stop after a second pull after the signal is lost.

P-27: there is a pulse signal (rising edge or falling edge), the relay is disconnected, there is no pulse signal, the relay pulls after a delay of time (considered continuous high-level or continuous low-level pulse).

P-28: after the power is turned on, the relay will be withdrawn after a delay period until the power is turned off.

P-31: after the power is turned on, the relay pulls in time A and turns off time B in an infinite loop; the power stops off.

P-32: there is a continuous signal, the relay pulls at one time, interrupts the B time, infinite loop; the signal disappears and the loop is terminated.

P-33: signal once, relay pulls at one time, interrupts B time, infinite loop; gives another signal to end the loop.

P-34: after the power is turned on, relay A pulls after the delay time and B cuts after the timely pull.

P-35: give a signal, a pulls and pulls after the delay time, relay B pulls and pulls.

P-36: a continuous signal is given. After A is exceeded, the relay is disconnected after B is turned on and turned on; the signal is lost, the timing is cleared, and the relay is switched off.

P-37: there is a signal, the relay will be disconnected automatically after it is turned off for a while, and the B time will be counted after the disconnection. The signal trigger is invalid for the duration A+B.

P-38: there is a signal, the relay will be automatically cut off after the withdrawal time-a, after the B time is counted after the interruption, it will be automatically cut off after the withdrawal time-again.

P-41: the signal does not move; The signal is lost and triggered; The relay absorbs and merges after a delay to disconnect.

P-42: the signal disappears. After the delay time, the relay pulls out; After the delay time, B, the relay interrupts.

P-43: the signal disappears. After passing the time of disappearance A, the relay pulls; after delaying the time B, the relay turns on.

P-44: after the power is turned on, the relay pulls in time A and turns off time B; after cycle C, the relay turns off and stops.

P-45: no action after power on; After the signal is given, the relay pulls for a while and interrupts the B time; The relay turns off and stops after the C cycle; when the signal is given, it is started again.

P-46: after the signal is given more than once, the relay pulls; continues to pull; the power stops.

P-47: after the signal has passed once, the relay pulls; when it pulls for time B, it is disconnected.

P-48: During the C period, after continuously giving the signal more than once, the relay is interrupted and stops after the B period.

Weight(Kg)